TM 5-3610-253-14
Table 5-17. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Cont
AN - Annually
W - Weekly
(Number) - Hundreds of Hours
B - Before
S
- Semiannually
M - Monthly
D - During
BI - Biennially
Q - Quarterly
A - After
For Readiness
ITEM TO BE INSPECTED
IN-
Reporting,
ITEM
Equipment Is
TER-
PROCEDURE
NO.
Not Ready/
VAL
Available If:
PAPER CUTTER - Cont
Check Light Barrier - Cont
6
B
Move backgauge forward or backward as necessary
2.
until backgauge position is displayed on
measurement display.
Check that the green LED is lit on the left
3.
housing.
Green LED
Cover each emitter diode individually and make
4.
sure green LED goes off and the red LED comes
does not go
off and/or
on.
red LED does
not come on.
5-347