TB 1-4920-443-35
e. Editing Hand Held Terminal Parameters
(1) To enable a built-in test (of the HHT) to be on power up or to set up any other HHT parameter,
simultaneously hold the CRTL and SHIFT keys while pressing F1 while the unit is connected to the
EPU (powered up).
(2) Once the initial menu appears, the following keys are used to make changes:
(a) F1: Moves forward in the list of values for current parameter.
(b) F2: Move forward in the list of parameters.
(c) F3: Moves backwards in the list of parameters.
(d) F4: Exits edit mode WITHOUT saving to Non-Volatile RAM inside terminal.
(e) F5: Exits edit mode and SAVES any changes to the Non-Volatile RAM.
f.
Default Terminal Parameters
(1) In order for the EPU to function properly with the Hand-Held Terminal, the terminal should already be
preset to the following parameters and checked by the user.
(2) Parameters with values specified in the "Options" column may be set to any of the specified values
shown. All other parameters must be set to what is shown in the "Expected Value" column.
Table 53-3 Defaulted Terminal Parameters
Parameter
Expected Value
Options
BAUD
9600
DATA BITS
7
PARITY
ODD
STOP BIT
1
DISPLAYPE
DISABLE
REPEAT
MEDIUM
SLOW-MEDIUM-FAST-NONE
KEY CLICK
ENABLE
ENABLE-DISABLE
KNP FUNC.
DISABLE
CURSOR
ENABLE
CURSOR BLINK
ENABLE
ENABLE-DISABLE
XON/OFF
DISABLE
HANDSHAKE
DISABLE
ECHO
DUISABLE
ESCAPE MODE
ANSI
CR/LF MODE
NEWLINE
TEST
DISABLE
ENABLE-DISABLE (Built-in-test)
SHIFT LOCK
DISABLE
81st Char
SCROLL
VIEW ANGLE
3
MIN, 2-7, MAX (LCD Contrast)
BREAK CMND
DISABLE
g. Enabling HHT Built-in-Test
(1) The HHT as shipped from the factory does NOT perform a self-test each time it powers up. To enable
the HHT BIT function, enter the EDIT menu by the procedure listed in paragraph a. above.
(2) Once in the edit mode, skip to the "TEST" parameter listed in the above paragraph by pressing F2
repeatedly until the word "TEST" appears at the top of the HHT display.
(3) Select "ENABLE" by pressing F1, then SAVE the parameters by pressing F5. Unplug the terminal
from the EPU, and plug it back in. The terminal should then execute its built-in test routines. If
desired, you may disable the automatic built-in test parameter by following the same procedure and
setting as the "TEST" parameter to DIASBLE.
h. Changing Shaft Constants With the HHT