TB 1-4920-443-35
a. Performance Check (T53/T55/T63/T64/714A Mode)
Ensure that the FEDS is in the T53/T55/T63/T64/714A test mode (Reference FEDS operator's manual).
Calibrate AEDATS concurrently with the vertical scale indicators.
(1) MT3:
0-50 PSIG (T53/T55/T63/64/714A)
Using the pressure calibrator, apply the following pressures to MT3 and record the results
Table 43-1 MT3 Alignment
Target
Calibrator
Vertical Scale
AEDATS
Pressure (psig)
Pressure (psig)
Top Row #2
( 1 PSI)
Indicator ( 1 PSI)
See Note below
VENT
10
20
30
40
50
RCAL=
NOTE
For AEDATS II Channel names, refer to AEDATS (H345-1) Technical Manual, Appendix C and for
AEDATS IV Channel names, refer to AEDATS (H355-7) Technical Manual. Chapter 6.
AEDATS Alignment MT3 - See Calibration of Automatic Data Acquisition H345-1 (AEDATS II),
or H355-7 (AEDATS IV) for FEDS Alignment requirements.
(2) MT4:
0-50 PSIG (T53/T64)
Using the pressure calibrator, apply the following pressures to MT4 for T53/T64 and record the results.
Table 43-2 MT4 -Alignment
Target
Calibrator
Vertical Scale
AEDATS
Pressure (psig)
Pressure (psig)
Top Row #4
( 0. 5 PSI)
Indicator (1 PSI)
See Note below
VENT
10
20
30
40
50
RCAL=
NOTE
For AEDATS II Channel names, refer to AEDATS (H345-1) Technical Manual, Appendix C and
for AEDATS IV Channel names, refer to AEDATS (H355-7) Technical Manual. Chapter 6.
AEDATS Alignment MT4 - See Calibration of Automatic Data Acquisition H345-1
(AEDATS II), or H355-7 (AEDATS IV) for FEDS Alignment requirements.