ARMY TM 9-6675-349-12&P
MARINE CORPS TM 11039A-12&P
Table 3-6 Parts Required for Transfer to
UH-60 Helicopter
Item
Purpose
Quantity
Part Number
UH-60 Indexer
Mounts CDU mount to IPADS frame.
1
7170186-9
UH-60 Power Cable
Connects IPADS to aircraft power.
1
7204116-2
Belt Assembly
Secure IPADS frame to aircraft.
2
CGU-1-B Class 2
CDU Mount Assembly
Attaches CDU to INDEXER
1
7204149-9
Cable Ties
Secures power cable to seats and overhead tube
10
MS3367-2-0
Plumb Bob Bracket
Supports plumb bob
1
7170187-1
Upper Stop Bracket
Vertical plumb bob bracket support
1
7170189-1
Lower Stop Bracket
Horizontal plumb bob bracket support
1
7170188-1
a.
Prepare helicopter for IPADS transfer.
(1) IPADS operator will request the crew chief remove and stow two seat sections indicated in Figure 3-9.
Figure 3-9 UH-60 Cockpit and Troop Compartment Layout
(2) Verify with UH-60 crew chief that power is applied in aircraft.
(3) Before starting installation procedures ensure the UH-60 APU is running.
(4) Verify with crew chief that UTILITY RECP 7.5 AMP circuit breaker is off. This is located on the #1
primary DC bus circuit breaker panel.
(5) Plug in headset to communicate with crew.