TM 5-6675-325-14
(j) Set auto-scaler B/ACCU/A/OFF switch to A.
(k) Set auto-sealer MAN/AUTO switch to MAN.
(1) Set auto-sealer X MEMORY switch to 1.
(m) Set calculator
(n) Set calculator
(o) Set calculator
OFF/ON switch to ON.
MAN/TRACE/NORM switch to NORM.
PRGM/RUN switch to RUN.
(3) Set up planimeter for area measurement (paragraph 5-6.20).
CAUTION
Hold magnetic cards by edge. Be sure hands are clean. Grease, oil, or
other materials may damage magnetic cards.
(4) Load preprogrammed card (paragraph 5-6.2h), Program I, into calculator.
(5) Tape map or drawing to remeasured to table.
(6) If needed, aline planimeter with tracer arm length selected (paragraph
5-6.20).
Record RT value.
NOTE
Factory determined RT value is given on Calibration Records Sheet
provided with equipment.
Alinement is performed as a check.
(7) Position planimeter near shape to remeasured so that tracer arm lies
along imaginary line through center of shape.
(8) Set wheels so that their axles form 90 degree angle with tracer arm.
(9) Enter into calculator horizontal and vertical scales of shape and RT
value.
5-59