TM 5-6675-325-14
(12) Select starting point for measurement, and mark.
(13) Set dot of lens tracing assembly over starting point.
(14) Press CLEAR button to clear auto-sealer.
(15) Trace boundary line of shape using dot in 1 ens tracing assembly. Stop
when you return to starting point.
(16) Multiply numbers shown in auto-scaler LED display to obtain area of shape
in square feet.
NOTE
If first significant digit of CA is in ones column (one place to left
of decimal point), multiply auto-scaler LED display by 10.
If first significant digit is in tens column, multiply auto-scaler LED
display by 100.
If first significant digit is three or more places to left of decimal
point, increase multiplication factor by 10 for each position it lies
further to left.
Measuring lengths with linear measuring probe to be added and/or subtracted.
(1) Assemble QPS with linear measuring probe.
(2) Activate QPS:
(a) Plug foot switch into PRINT input jack on back panel of auto-scaler.
(b) Plug remote tracer switch into ACCU input jack on back panel of
auto-scaler.
(c) Plug linear measuring probe into El, encoder socket on back panel of
auto-scaler.
(d) Plug power
auto-scaler.
(e) Plug power
(f) Plug power
transformer cable into POWER supply jack on back panel of
transformer cable into wall outlet.
cord into wall outlet.
(g) Set
(h) Set
(i) Set
(j) Set
encoder OFF/E2E1 switch on back panel of auto-scaler to El.
AUDIO/OFF switch on back panel of auto-scaler to AUDIO.
auto-scaler B/ACCU/A/OFF switch to A.
auto-scaler MAN/AUTO switch to MAN.
5-63