TM 5-6675-319-14
2-16.6 Adjust Developer Thermostat.
MOS:
83FJ6, Reproduction Equipment Repairer
TOOLS:
Flat Tip Screwdriver
Bimetallic Thermometer
SUPPLIES:
Rubber Matting
WARNING
Electrical shock hazard. You must stand on rubber matting while performing
this this procedure. Death or serious injury may occur.
CAUTION
Do not use mercury-filled thermometer to check temperature. Breakage could
result and cause serious mercury contamination of unit.
NOTE
Adjustment shall be performed with DRYER THERMOSTAT set at 110°F (43.3°C)
and FILM TRANSPORT SPEED indicator set at 30 in. per min.
a.
Turn on processor and allow developer temperature to stabilize.
b. Remove screws and rear access cover.
c .
Remove plastic drip cap from DEVELOPER heater thermostat.
2-98