TM 5-6675-319-14
2-16.9 R e p a i r F l o w m e t e r.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS:
F l a t T i p S c r e w d r i v er
Cross Tip Screwdriver
Hose Clamp Pliers
6 in. Adjustable Wrench
Tube Cleaning Brush
5/32 in. Hex Head
SUPPLIES:
Flowmeter Tube
Valve Assembly
Key Wrench
Kit (Developer & Fixer)
0-Rings
WARNING
t u r n e d o f f b e f o r e s e r v i c i n g.
a.
T u r n o f f c i r c u i t b r e a k e r.
NOTE
Perform this maintenance procedure
b. Remove left side panel.
Death or serious injury may occur from electrical shock unless power is
only when tanks are drained.
c .
Disconnect input and output lines from rear of flowmeter with clamp
p l i e r s .
2-102