TM 5-6675-319-14
2-16.7 Adjust Film Detector Crossover Assembly.
MOS: 83FJ6, Reproduction Equipment Repairer
TOOLS: 6 in. Adjustable Wrench
SUPPLIES: Photographic Paper
CAUTION
Use light pressure when closing flowmeter control valves or damage will
r e s u l t .
NOTE
Flowmeter control valves must be closed for adjustment of detector roller
microswitches.
a.
Turn on PUMP switch
b . I n s e r t p h o t o g r a p h i c
e n t r a n c e r o l l e r s.
and close flowmeter valves.
Remove top cover.
paper to one side, between the detector crossover
c .
d.
e.
f .
2-100
Tighten the adjusting nut until the pumps operate. Then tighten nut an
a d d i t i o n a l o n e - s i x t h t u r n.
Repeat procedure for other side of rollers.
Remove paper strip and open flowmeter valves.
Turn off PUMP switch and replace top cover.