TM 5-3610-287-24
2-61.
WARNING
ELECTRICAL HAZARD. Turn off main power switch before
connecting or disconnecting expanding side power cable.
Failure to do so may result in death or serious injury.
NOTE
Curbside and roadside expanding side power cable connectors
are not identical.
1.
Set MAIN POWER switch to OFF.
2.
Loosen screws (1) securing cover plate (2) to junction box (3).
Tag and disconnect wires (4) from junction box terminals (5).
3.
4.
Loosen screws (6) securing strain relief clamp (7) to junction
box (3). Remove power cable (8).
Pull power cable (8) through strain relief clamp (7).
5.
6.
Install new power cable (8) through strain relief clamp (7).
Tighten screws (6) securing strain clamp (7).
7.
8.
Install new terminal ends (9) on wires (4).
9.
Connect wires (4) to junction box terminals (5).
Install cover plate (2) with screws (1).
10.
Install power cable connector (a, this para).
11.
REPAIR SECTION BODY
SKIN (TEMPORARY)
Section body skin is temporarily repaired with tape.
INITIAL SETUP
Materials/Parts
2-195