TM 5-3610-287-24
WARNING
ELECTRICAL HAZARD. Turn off main power switch before
connecting or disconnecting expanding side power cable.
Failure to do so may result in death or serious injury.
NOTE
Curbside and roadside expanding side power cable connectors
are not identical.
1.
Set MAIN POWER switch to OFF.
2. Disconnect expanding side power cable (1) from wall receptacle (2).
3. Set MAIN POWER switch to ON.
4.
Remove screws (3) and lockwashers on strain relief clamp (4).
5.
Unscrew strain relief clamp (4) and seal (5). Separate from connector
housing (6).
2-192