TM 5-3610-286-20
Table 2-5. Organizational Troubleshooting (cont).
Malfunction
Test or inspection
Corrective action
22. AIR BLAST GAGE INDICATES LOW OR NO PRESSURE (cont).
Step 2.
Check that air lines are serviceable.
Replace faulty air lines.
Step 3.
Remove air line from pressure gage and start compressor; check for proper
airflow.
If airflow is present, pressure gage is faulty. Refer to next higher
maintenance.
If airflow Is low or no pressure is present, check compressor for binding
or dirt before replacing (para. 2-91).
23. PRINTING PRESS DOES NOT STOP IMMEDIATELY (COASTS) WHEN SAFETY STOP PUSHBUTTON
IS PRESSED.
WARNING
HIGH VOLTAGE
Do not operate printing press until you are sure TSS Press Section is
connected to a suitable ground. Failure to do so may result in death or
serious injury.
Shut off power source before attempting to disconnect, service, or con-
wires or cables. Failure to do so may result In death or serious injury.
When working on high-voltage components, always have another person
present, and keep one hand away from equipment to reduce hazard of
current flowing through vital organs of body, Remove all jewelry from
fingers, wrists, and neck prior to working on electrical components.
Failure to do so may result in death or serious burns.
Step 1.
Step 2.
2-54
Check drive belt for wear and proper adjustment.
If belt is worn or not properly adjusted, adjustor relate drive belt
(para. 2-80).
If belt is good, go to step 2.
Check that main motor brake is not hung up in release position.
If condition persists, refer to next higher level of maintenance.