Table 2-5. Organizational Troubleshooting (cont).
Malfunction
Test or inspection
Corrective action
18. DELIVERY LIGHT DOES NOT OPERATE.
WARNING
HIGH VOLTAGE
l Do not operate printing press until you are sure TSS Press Section is
connected to a suitable ground. Failure to do so may result in death or
serious injury.
l Shut off power source before attempting to disconnect, service, or con-
nect wires or cables. Failure to do so may result in death or serious injury.
l When working on high-voltage components, always have another person
present, and keep one hand away from equipment to reduce hazard of
current flowing through vital organs of body. Remove all jewelry from
fingers, wrists, and neck prior to working on electrical components.
Failure to do so may result in death or serious burns.
Step 1.
Visually check fluorescent light for darkened color or breakage.
Replace fluorescent light (TM 5-3610-286-10).
Step 2.
Check starter (m9) for serviceability.
Replace starter (m9) (TM 5-3610-286-10).
Step 3.
Using a multimeter set to range higher than 220V ac, check for 220V ac between
points L2 and L11.
If power is present, go to step 4.
If no power is present, go to step 7.
Step 4.
Using a multimeter set to range higher than 220V ac, check for 220V ac between
points L1 and L11.
If power is present, go to step 5.
If no power is present, replace fuse (e14).