TM 5-3610-286-20
Table 2-5. Organizational Troubleshooting (cont).
Malfunction
Test or inspection
Corrective action
19. STATIC ELIMINATOR DOES NOT OPERATE (cont).
Step 1.
Step 2.
Step 3.
Step 4.
Step 5.
Step 6.
Check that compressor is running.
If not running, check compressor switch.
If running, go to step 2.
With main power on, compressor on, and power unit of static eliminator on,
check that light at power unit is lit.
If light is not lit, go to step 2.
If light is lit, replace static eliminator bar (para. 2-83).
With main power on, compressor on, and power unit of static eliminator on, use
a multimeter set to range higher than 220V ac to check for 220V ac at power unit
power unit light receptacle terminals.
If power is present, replace light at power unit (para. 2-83).
If no power is present, go to step 4.
With main power on, compressor on, and power unit of static eliminator on, use
a multimeter set to range higher than 220V ac to check for 220V ac at points 1 and
2 of power unit input terminal.
If power is present, replace power unit (para. 2-83).
If no power is present, go to step 5.
Using a multimeter set to range higher than 220V ac, check for 220V ac at points
0 and 220 on transformer (m60).
if power is present, go to step 6.
If no power is present, replace transformer (m6) (para. 2-93).
Using a multimeter set to range higher than 220V ac, check for 220V ac at points
L2 and L11 of terminal strip.
if power is present, go to step 7.
If power is not present, check wiring using schematic (figure FO-1).
2-51