Table 2-5. Organizational Troubleshooting (cont).
Malfunction
Test or inspection
Corrective action
18. DELIVERY LIGHT DOES NOT OPERATE (cont).
Step 5.
Step 6.
Step 7.
Step 8.
Using a multimeter set to ohms range, check for continuity across starter (m9).
If continuity is present, go to step 6.
If no continuity is present, replace starter (m9) (TM 5-3610-286-10).
Using a multimeter set to ohms range, check for continuity at blackout switch.
If continuity is present, go to step 7.
If no continuity is present, replace blackout switch (para. 2-93).
Using a multimeter set to range higher than 220V ac, check for 220V ac at points
0 and 220 on transformer (m6).
if power is present, go to step 8.
if no power is present, replace transformer (m6) (para. 2-93).
Check wiring using schematic (figure FO-1).
If wiring is good, replace light fixture (para. 2-54).
if wiring is not good, replace wiring.
19. STATIC ELIMINATOR DOES NOT OPERATE.
WARNING
HIGH VOLTAGE
Do not operate printing press until you are sure TSS Press Section is
connected to a suitable ground. Failure to do so may result in death or
serious injury.
Shut off power source before attempting to disconnect, service, or con-
nect wires or cables. Failure to do so may result in death or serious injury.
When working on high-voltage components, always have another person
present, and keep one hand away from equipment to reduce hazard of
current flowing through vital organs of body. Remove all jewelry from
fingers, wrists, and neck prior to working on electrical components.
Failure to do so may result in death or serious burns.
2-50