Table 2-5. Organizational Troubleshooting (cont).
Malfunction
Test or inspection
Corrective action
23. PRINTING PRESS DOES NOT STOP IMMEDIATELY (COASTS) WHEN SAFETY STOP PUSHBUTTON
IS PRESSED (cont).
Step 3.
Using multimeter set to ohms range, check continuity between Point F6 and Point
F16 on brake main motor limit switch (b50).
If no continuity is present, limit switch (b50) is faulty. Refer to next higher
level of maintenance.
If continuity is present, main motor brake is faulty. Refer to next higher
level of maintenance.
24. PRINTING PRESS DOES NOT STOP WHEN CYLINDER GUARD IS REMOVED.
Using a multi meter set to ohms scale, check for shorted cylinder guard switch (b135)
between Point 243 and Point 244, using current path 77 (figure FO-1).
Replace shorted cylinder guard switch (b135) (para. 2-65).
25. PRINTING PRESS DOES NOT STOP WHEN SAFETY GUARD OR FINGER SAFETY GUARD
IS TRIPPED.
Using a multimeter set to ohms scale, check ink unit finger safety guard switch (b30) and
ink roller safety guard switch (b26) for continuity.
Replace faulty safety switches (paragraphs 2-16, 2-74).
SECTION V. Maintenance Procedures
2-11.
General. This section contains maintenance procedures which are the responsibility of the
organizational maintenance personnel as authorized by the MAC in appendix B. The following topics
will be included as applicable: a. Inspect, b. Service, c. Adjust, d. Remove, e. Repair, f. Install.
For repair procedures which include disassembly, inspect all components of the assembly and
replace any items which are badly worn or damaged. For specific maintenance of the TSS Press
Section and semitrailer, refer to TM 5-3610-287-14 and TM 5-2330-305-14.
a. Maintenance Personnel Unless otherwise specified in the setup, all maintenance procedures
in this section are performed by a Printing and Binding Repairman MOS 83F20J6. When a second
person is needed to aid in removal of a heavy component, that person will be a crew member: Printing
and Binding Specialist MOS 83F20. An Electrician MOS 35E20 must be designated if any electrical
leads are to be disconnected.
2-55