TM 5-3610-285-14
NOTE
It is not necessary to remove the phenolic block that supports the pump housing.
(5)
Remove two screws and bracket, and release the pump assembly from processor frame.
(6)
Move developer recirculation pump assembly as necessary to remove three hoses. Remove hoses and
move pump assembly aside.
(7)
Cut wire ties securing pump wiring to processor frame. Trace pump wiring to electrical control panel.
(8)
Push strain relief upward until it separates sufficiently to allow passage of wiring.
(9)
Tag and disconnect pump wiring from terminal block. Disconnect ground wire.
(10)
Remove defective developer recirculation pump assembly, with attached wiring, from processor.
(11)
Install new developer recirculation pump assembly into processor.
(12)
Lead new pump wiring through frame to electrical control panel, and through strain relief.
(13)
Connect new wiring to terminal block. Connect ground wire.
(14)
Perform steps a. (18) through a. (26).
(15)
Refill developer tank.
(16)
Reinstall guard and secure with screw.
(17)
Replace top cover and left access panel.
(18)
Turn on processor circuit breaker.
5-192