TM 5-3610-285-14
(13)
Push strain relief upward from frame until it separates sufficiently to allow passage of wiring. Tag and
disconnect pump wiring from terminal block, relay U4, and from common ground.
(14)
Remove defective fixer recirculation pump assembly, with attached wiring, from processor.
(15)
Install new fixer recirculation pump assembly into processor.
(16)
Lead new pump wiring through frame to electrical control panel, and through strain relief.
(17)
Connect new wiring to terminal block, terminals on relay U4, and to common ground.
(18)
Push down on strain relief until it seats firmly.
(19)
Install new wire ties to wiring and processor frame.
(20)
Reattach hoses to hose fittings on new pump housing. Tighten hose clamps securely.
(21)
Install pump to processor frame and secure with bracket and two screws.
(22)
Replace fixer and developer pump splash cover.
(23)
Reinstall drain header cover and secure with screws.
(24)
Reinstall drain valve handles. Secure with screws.
(25)
Reinstall front control panel and secure with screws.
(26)
Reinstall TRANSPORT SPEED control knob. Tighten setscrew.
(27)
Refill fixer tank.
5-190