TM 5-3610-253-14
c.
Remove the access plate above the hydraulic pump.
NOTE
If the hydraulic fluid is to be reused, be sure that the pail is clean
before pumping fluid into it.
d. Using evacuation pump, pump all hydraulic fluid from the reservoir.
e.
f. Remove the hydraulic pump pulley.
WARNING
Dry cleaning solvent, P-D-680, used to clean parts is potentially dangerous
to personnel and property. Avoid repeated and prolonged skin contact.
Wear solvent impermeable gloves and eye/face protective equipment when using
solvent. Do not use near open flame or excessive heat. Flash point of
solvent is 100 F to 138 F (38 C to 59 C).
Remove pump filter and pipes connected to pump. Clean filter with
g.
solvent and dry thoroughly.
h. Remove mounting bolts, plate and defective pump.
i.
Remove base plate from bottom of defective pump. Do not retain O-rings.
5-558