TM 5-3610-253-14
Table 5-23. DIRECT/GENERAL SUPPORT TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
15. CLAMP RETURNING TOO SLOWLY, OR NOT AT ALL - Cont
Step 3.
Check that locking valve (M1) is energized and/or not jammed.
(a) Test locking valve and replace defective parts (paragraph
(b) If not defective, proceed to step 4.
Step 4.
Check that clamp ball valve (M2) is de-energized.
Test clamp ball valve and replace defective parts (paragraph
16. ROUGH FOOT PEDAL MOVEMENT.
Check for hesitation in clamp control valve.
If clamp control valve hesitates, replace P1 block (paragraph
17.
CLAMP DOES NOT DESCEND.
Check that locking valve (M1 is energized.
(a) Perform locking valve test and replace defective parts
(b) If malfunction persists, refer to electrical and electronic
schematics and troubleshoot.
18. NO KNIFE INCHING MODE.
Step 1.
Check for improper clutch pressure.
(b) If pressure is correct, proceed to step 2.
Step 2.