TM 5-3610-253-14
Table 5-8. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
18. MAIN MOTOR WILL NOT START.
Step 1.
Check to see that main motor overload relay is on (-), and not
tripped.
(a) If main motor overload relay is not tripped, proceed to step
2.
(b) If tripped, reset overload relay. If relay trips again,
proceed to step 4.
(c) If relay does not trip again and main drive motor is still
inoperable, proceed to step 2.
Step 2.
Check for power to main motor overload relay.
(a) Turn main power switch to 0 position.
(b) Remove main drive motor overload relay cover.