MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
17.
BACK GAUGE DOES NOT OPERATE ELECTRICALLY.
Step 1.
Remove backgauge V-belt cover and check for motor operation.
(a) If motor operates, adjust or replace V-belts (paragraph
(b) If motor does not operate, proceed to step 2.
Step 2.
Check to see that backgauge motor overload relay is on (I), and not
tripped.
(a) Reset overload relay.
If relay trips again, proceed to step
5.
(b) If relay does not trip again and backgauge is still
inoperable, proceed to step 3.