TM 5-3610-253-14
Table 5-8. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
18. MAIN MOTOR WILL NOT START - Cont
THREE-PHASE MOTOR TESTS
Test Lines at Terminals
3-5 ohms
U and X
3-5 ohms
V and Y
3-5 ohms
W and Z
(b) If readings are incorrect, replace main drive motor
(c) If correct, replace cabling between overload relay and main
drive motor.
5-126