TM 5-3610-253-14
Table 5-8. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
17. BACKGAUGE DOES NOT OPERATE ELECTRICALLY - Cont
WARNING
Electrical shock hazard. You must stand on rubber matting as a protective
measure before performing this procedure. Death or serious injury may
occur.
(e) Check for 120 5 V ac at output of three contacts on overload relay
while using backgauge controls.
(1) If voltage is present, proceed to step 5.
(2) If voltage is not present, proceed to step 4.
Check for 120 5 V ac at input of three contacts on overload relay
Step 4.
while using backgauge controls.
(a) If voltage is present, replace overload relay (paragraph
(b) If voltage is not present, refer to direct/general support
maintenance.
Step 5.
5-122