TB 1-4920-443-35
AEDATS II T53 ALIGNMENT WORKSHEET
(j) Channel 4
Output(mAvg)
(Vert. Scale)
(Limits)
AEDATS II
Meter
(V4)
____________
____________
Shorted
100hz
116.5
____________
.9-1.1
____________
100hz
233.0
____________
1.9-2.1
____________
100hz
350.0
____________
2.9-3.1
____________
100hz
466.0
____________
3.9-4.1
____________
100hz
583.0
____________
4.9-5.1
____________
(k) Channel 5
Output(mAvg)
(Vert. Scale)
(Limits)
AEDATS II
Meter
(V5)
____________
____________
Shorted
100hz
116.5
____________
.9-1.1
____________
100hz
233.0
____________
1.9-2.1
____________
100hz
350.0
____________
2.9-3.1
____________
100hz
466.0
____________
3.9-4.1
____________
100hz
583.0
____________
4.9-5.1
____________
(12)Engine oil inlet temperature gauge T53/T55 (Decade Box)
(f) Connect the decade resistor to pins N and P of the flight harness cable connector (T53), or
pins K and N of the flight harness cable connector (T55). Adjust the decade resistor to obtain
the gauge indications listed below.
NOTE
The 0-400 temperature gauge will read approximately 20 degrees high because of
resistance in the wiring from the control cab to the engine.
Decade Resistor
Reading
Avg
Analog Gage
(Ohms)
+/-10 F
90.34-90.42
____________
32F
90.4
97.27-97.35
____________
68F
97.3
104.56-104.64
____________
104F
104.6
111.78-112.78
____________
140F
112.3
119.86-120.86
____________
176F
120.4
128.35-129.35
____________
212F
128.8
141.80-143.00
____________
266F
142.4
151.31-152.51
____________
302F
151.9
176.95-178.95
____________
392F
177.9
128