TB 1-4920-443-35
AEDATS II T53 ALIGNMENT WORKSHEET
(d) MT2
0-300 psig combustor static diffuser
1 Using the pressure calibrator, apply the following pressures to MT2, and record the results.
Vertical Scale top row 2
AEDATS 2
5SE01313-20
Actual
AEDATS 2
6SE00950-5
Vertical Scale Channel name
Pressure
Pressure
(*)
(*)
(psig)
psi
+/- 1 psi
+/- 2 psi
T55 PDO
Vent
____________
____________
____________
L714 PT3
100
____________
____________
____________
150
____________
____________
____________
200
____________
____________
____________
250
____________
____________
____________
300
____________
____________
____________
R-cal
____________
(e) MT-5 0-200 psig Oil scavenge Pressure
1 Using the pressure calibrator, apply the following pressures to MT-5, and record the results.
Vertical Scale top row 7
AEDATS 2
5SE01313-7
Actual
AEDATS 2
6SE00950-4
Vertical Scale Channel name
Pressure
Pressure
(*)
(*)
(psig)
psi
+/- 1 psi
+/- 2 psi
T53 pso
Vent
____________
____________
____________
____________ T63 Eop_ret
40
____________
____________
80
____________
____________
____________
120
____________
____________
____________
160
____________
____________
____________
200
____________
____________
____________
R-cal
____________
(f) MT-6 0-200 psig Torque meter Pressure
1 Using the pressure calibrator, apply the following pressures to MT-6, and record the results.
Vertical Scale top row 5
AEDATS 2
5SE01313-7
Actual
AEDATS 2
6SE00950-4
Vertical Scale Channel name
Pressure
Pressure
(*)
(*)
(psig)
psi
+/- 1 psi
+/- 2 psi
T53 TP
Vent
____________
____________
____________
T55 p2b
40
____________
____________
____________
____________ T63 TorqPSI
80
____________
____________
L714 P2b
120
____________
____________
____________
160
____________
____________
____________
200
____________
____________
____________
R-cal
____________
130