TB 1-4920-443-35
AEDATS II T53 ALIGNMENT WORKSHEET
(m) MT-13 0-50 psig Dyno inlet Pressure
1 Using the pressure calibrator, apply the following pressures to MT-13, and record the results.
Vertical Scale bottom row 11
AEDATS 2
5SE01313-4
Actual
AEDATS 2
6SE00950-2
Channel name
Pressure
Pressure
(*)
Vertical Scale
(*)
(psig)
psi
+/- 1 psi
+/- 2 psi
____________ T53 Pdyn_sup
Vent
____________
____________
____________ T55 Pdyn_sup
10
____________
____________
____________ T63 Pdyn_sup
20
____________
____________
L714 Pdyn_sup
30
____________
____________
____________
40
____________
____________
____________
50
____________
____________
____________
R-cal
____________
(n) MT-20 0-50 in-h2o P1 Air Pressure P1 air panel
1 Access MT-20 in the J-box. Connect the low pressure calibrator directly to the transducer.
Apply the following pressures to MT-20, and record the results.
AEDATS 2
5SE01313-19
Digital
AEDATS 2
Channel name
Pressure
Indicator
(*)
(*)
(in-h20)
+/-2 psi
+/- 1 psi
T53 P1air
Vent
____________
____________
10
____________
____________
20
____________
____________
30
____________
____________
40
____________
____________
50
____________
____________
133