TB 1-4920-443-35
AEDATS II T53 ALIGNMENT WORKSHEET
(d) Set to second mode
1 CAL:V=9.497 I=19.601
2 Display should read 9.497v
3 TB 609 1 (+) 2 (-) _______________ +/-20mv
4 J2 CONN=3333 HZ
5 Enter second point in AEDATS (712) 18994, (714) 22793
Satisfactory? Y/N
(e) Disconnect cable P/N 20090761-1 from torque sensor cable
(reference Step 53B)
(g) Set Performance Monitor to Normal
HP
RPM
TQ
CALC. H.P.
181.4. Hz.=780 rpm ____________ ____________ ____________ ____________
272.1 Hz..=1170 rpm ____________ ____________ ____________ ____________
453.5 Hz.=1940 rpm ____________ ____________ ____________ ____________
725.6 Hz.=3100 rpm ____________ ____________ ____________ ____________
907.0 Hz.=3880 rpm ____________ ____________ ____________ ____________
HP = TQ x RPM/ 63024 Army
HP = TQ x RPM/ 5252 Air Force
NOTE: Army TQ is measured in (in-lb) Air force TQ is measured in (ft-lb)
(5) Verify RTD function of performance Monitor
(reference Step 53C)
(a) Connect to cable 20090761-1 pins I and J
(b) Hit mode switch one time to monitor Temperature
Temperature
Actual Temperature
Ohms
Deg F
+/- 8 deg F
100
32
____________
110
79
____________
120
126
____________
130
173
____________
140
222
____________
123