TB 1-4920-443-35
AEDATS II T53 ALIGNMENT WORKSHEET
(6) Fuel flow measurement CEC 2700 BOX T-53/T55/T63
(a) Ensure the system is in the T-53/T55 test mode, with the correct flight harness connected to the
J-box.
(b) Set calculating counter controls as follows: (Channel 4)
1 DEC
6
2C
01000
3 10n
0
4 Auto
depressed
5 X10
released
6 Sample Rate (fast)
1
7 Test
released
(c) Determine C settings for channel 4 Channel 4 C = (3600 x 8.337 x specific gravity) divided by the
turbine meter K-factor (Average from calibration sheet)
(d) Enter calculated value on channel 4 C switches
(e) At the fuel trailer disconnect MT-207 from the flowmeter and connect the test oscillator to pins A
(+) and B (-).
NOTE
(g) Enter Specific Gravity, K Factor and Temp in AEDATS to read PPH from flowmeter Cal sheet.
(h) Connect Temp source to TC 208 to correspond to flowmeter Cal Temp.
(i) Set the following points with test oscillator:
1 1 Vac input
(j) Note: oscillator frequency x c = PPH
(k) Enter S/G into AEDATS to read PPH from Cal sheet
(l) Input the following frequencies into connector MT207 pins A (+) and B (-).Lower Flowmeter.
Note: Cell constant Low K Factor (#3)
Oscillator Hz
Calculating Counter
AEDATS 2
Calculating Counter
AEDATS 2
+/- 1 Hz
Sheet Hz
+/- .35 % PPH
(WF)
(WF)
+/- 1 Hz
+/- .35 % PPH
250Hz
____________
____________ ____________
____________
____________
500Hz
____________
____________ ____________
____________
____________
750Hz
____________
____________ ____________
____________
____________
1000Hz
____________
____________ ____________
____________
____________
1250Hz
____________
____________ ____________
____________
____________
(Note: frequency x C = PPH) (CH 4C= 3600 x 8.337 x SG /K factor)
124