TB 1-4920-443-35
(7) Set the vertical scale ZERO control for a TI indication of 0 deg.
(8) Set the Voltage Calibrator output controls for 12.00 VDC.
(9) Enter 150 as the second TI AEDATS II Alignment point, then press the return key. After 150 is
entered, the TI AEDATS II screen will request Satisfactory Y/N? Do not make a selection at this time.
(10)Set the Vertical Scale SPAN control for a TI indication of 150 deg.
(11)Set the Voltage Calibrator for minimum output.
(12)Set Voltage Calibrator output controls for the values listed.
(13)The TI AEDATS II screen and the Vertical Scale must indicate within the corresponding values listed.
(14)Record results.
(15)After the last test point, enter Y to satisfy the AEDATS II request for Satisfactory Y/N?, then press the
return key.
Table 65-1 Throttle
Voltage Input
AEDATS 4
Vertical Scale
(VDC)
Throttle
Bottom Row #1
(0.5 %)
Indicator (1.0 %)
0
(0 %)
2.4
(30 %)
4.8
(60 %)
7.2
(90 %)
9.6
(120 %)
12
(150 %)
NOTE
For AEDATS II Channel names, refer to AEDATS (H345-1) Technical Manual, Appendix C
and for AEDATS IV Channel names, refer to AEDATS (H355-7) Technical Manual. Chapter 6
(16)Set the Voltage Calibrator for minimum output.
(17)Disconnect the Voltage Calibrator from N1 POS.
(18)Reconnect N1 POS. to engine.