TB 1-4920-443-35
Table 28-2 Alignment Points for T700 Type-J Thermocouple Channels
Channel
Connector
DORIC
AEDATS
Calibrator
DORIC and AEDATS
DORIC
AEDATS
Name
Channel
Channel
Temp (F)
Tolerance Limits ( 1)
Reading
Reading
Engine
*
32
31 to 33
P56 or
BSUMP
Lube
100
99 to 101
Eng Lube
1
Discharge
200
199 to 201
Disch Temp
Temp.
300
299 to 301
*
32
31 to 33
Engine Oil
100
99 to 101
Scav.
P57
2
J02
200
199 to 201
Temp.
300
299 to 301
32
31 to 33
Inlet Air
70
69 to 71
P58
3
T21
Temp
100
99 to 101
120
119 to 121
32
31 to 33
Inlet Air
70
69 to 71
P59
4
T22
Temp
100
99 to 101
120
119 to 121
32
31 to 33
Inlet Air
70
69 to 71
P68
5
T23
Temp
100
99 to 101
120
119 to 121
32
31 to 33
Inlet Air
70
69 to 71
P92
6
T24
Temp
100
99 to 101
120
119 to 121
32
31 to 33
Inlet Air
70
69 to 71
P101
27
T25
Temp
100
99 to 101
120
119 to 121
32
31 to 33
Inlet Air
70
69 to 71
P102
28
T26
Temp
100
99 to 101
120
119 to 121
32
31 to 33
Inlet Air
70
69 to 71
P103
29
T27
Temp
100
99 to 101
120
119 to 121
32
31 to 33
Inlet Air
70
69 to 71
P104
30
T28
Temp
100
99 to 101
120
119 to 121
*
32
31 to 33
Dyno-lube
100
99 to 101
Inlet
J20 of Dyno
7
Tdyn_tnk
200
199 to 201
Temp.
300
299 to 301
*
32
31 to 33
Dyno-lube
100
99 to 101
J21 of Dyno
8
Tdyn_fwd
Fwd Temp.
200
199 to 201
300
299 to 301
*
32
31 to 33
Dyno-lube
100
99 to 101
J22 of Dyno
9
Tdyn_aft
Aft Temp.
200
199 to 201
300
299 to 301
*
32
31 to 33
See note
Dyno-lube
(below)
100
99 to 101
Delta
none
Tdyn_FA
J20,J23,
200
199 to 201
Temp.
and J24
300
299 to 301
To align Dyno-lube delta temperature, disconnect J24, install thermocouple at J20, and Connect Calibrator at J23. *
The Limit Control Panel (paragraph #37) may be calibrated in conjunction with the channels marked by "*"