ARMY TM 9-6675-349-12&P
MARINE CORPS TM 11039A-12&P
Table 4-2. Operator Preventive Maintenance Checks and Services continued
Item
Interval
Item to be
Procedure
Equipment Not
No.
Inspected
Ready/Available If
B
D
A
W
M
CAUTION
6
Battery
Good
IPADS may shut down if disconnected
indicator
from vehicle power and the charge state
indicator is not illuminated. Check that
BCU Battery Good Indicator is illuminated.
New batteries require 2 hours to charge.
7
CDU status
During CDU boot up, check status display
Any indicated failure.
display
for failure indications. Check that audible
alarm is operational. With switch in
STLTH position, check that screen dims
and sound decreases. With switch in KBD,
9
Battery Test
NOTE
This test provides a check of IPADS
battery operation under load. A battery test
will be performed at the end of a mission to
minimize the impact of a defective battery
and IPADS shutdown.
a. While IPADS is operating, note that the
BCU Battery Good indicator is illuminated.
b. Disconnect vehicle power by setting
BCU DC INPUT power switch to OFF.
IPADS should remain operating with the
input power indicator dark.
c. After 30 seconds of battery operation,
either set BCU DC INPUT power switch
DC INPUT to ON to continue operation or
turn IPADS off.
10
BCU
Inspect BCU batteries for cracked case,
Case is cracked, or
batteries
leakage, or corrosion.
leakage or corrosion
is present.
11
BCU
Inspect connectors for bent or damaged
Cable connector pins
connectors
pins and covers are present and attached.
are damaged.
4-5