TM 5-6675-323-14
NOTE
Wiring is connected to cover and switches.
d. Remove bezel nut.
Tag and desolder wires from potentiometer.
e.
f. Withdraw grid intensity control potentiometer and locktooth washer from
rear of control box.
g. Solder wires to new grid intensity control potentiometer.
Install potentiometer and locktooth washer and secure with bezel nut.
h.
Reinstall control knob and tighten socket head screws.
i.
NOTE
Be certain wires are not loose, crossed, or disconnected before securing
cover. Green (ground) wire is connected to cover screws.
j. Reinstall cover on lamp control box and secure with socket head
screws.
k. Plug in power cord and turn power on.
6-47