TM 5-6675-323-14
c.
Deflate air shocks to allow access to retaining bolts. Remove
retaining bolts from air shocks.
d. Block table frame.
e.
Remove side braces.
( 1 ) Remove capscrews and washers from sides and base of table.
(2) Remove shims.
(3) Slide braces out from underneath table.
g.
WARNING
S e r i o u s injury to personnel or damage to equipment may occur unless two
or more personnel are used to remove and install the split-stage light
table.
This equipment weighs 360 lbs.
h. Slide defective table to center aisle and remove from section.
i.
Install new table and secure front legs with bolts.
Secure rear legs of table with bolts.
j.
k. Reinstall shims and side braces, and secure with capscrews and
washers.
CAUTION
D o not inflate air shocks over 70 psi or damage t o e q u i p m e n t c o u l d r e s u l t .
l.
Reinstall
four
retaining
bolts
in
air
shocks.
Inflate
air
shocks.
m.
R e m o v e tape and uncoil power cord.
P l u g in power cord a n d turn power on.
n.
Contact your battalion for packing
6 - 1 7 . PREPARATION FOR STORAGE OR
SHIPMENT.
and shipping instructions.
6-51