TM 5-6675-323-14
Table 6-3. ORGANIZATIONAL TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
LIGHT GRID, FAN MOTOR, AND CARRIAGE CLUTCH SWITCHES ARE INOPERATIVE.
WARNING
Death or serious injury may occur from electrical shock unless power cord
is unplugged before servicing the split-stage light table.
S t e p 1.
R e m o v e two quick-disconnect screws and remove cover from power
panel.
S t e p 2.
Perform continuity check for ON/OFF switch at terminal board.
If no continuity is present, replace ON/OFF switch (paragraph
2.
LIGHT GRID INTENSITY WILL NOT CHANGE.
(a) If no continuity is present, replace potentiometer (paragraph
(b) Notify direct support maintenance for reversal of dimmer card
connector or replacement of dimmer circuit card.
3. ONLY ONE LIGHT GRID LIGHTS.
Inspect connections to light grid.
(a) Tighten loose connections.
(b) Notify direct support maintenance for replacement of dimmer
circuit card.
4. FAN MOTOR WILL NOT RUN. LIGHT GRIDS AND CLUTCHES WORK.
Notify direct support maintenance for replacement of fan.
6-42