Table 2-4. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
DRYER HEATER DOES NOT WARM DRYING AIR - Cont
(1) If no continuity exists, replace thermostat.
( 2 ) I f c o n t i n u i t y i s p r e s e n t , r e f e r t o d i r e c t / g e n e r a l s u p p o rt
maintenance for replacement of dryer over temperature
thermostat or dryer heater (paragraph 2-20.9).
4.
PAPER DOES NOT TRAVEL AT SPEED INDICATED ON TRANSPORT SPEED INDICATOR.
Check for improperly adjusted TRANSPORT SPEED indicator as follows:
(a) Turn on circuit breaker and DRIVE switch.
(b) Mark several sheets of photographic paper at 12 in. intervals.
(c) Set TRANSPORT SPEED at 12 in. per minute.
(d) Feed paper into processor, noting time required for 12 in. to pass a
r e f e r e n c e p o i n t.
(e) Compute speed of paper travel in inches per minute.
Adjust transport speed if computation varies from TRANSPORT SPEED
indicator (paragraph 2-16.3).
5.
AFTER WARM-UP, DEVELOPER THERMOMETER DOES NOT READ 80°F (26.6°C).
Step 1.
Check DEVELOPER thermometer reading.
(a) With processor activated and PUMP switch on, remove top cover
and developer/fixer crossover.
2-80