TM 5-6675-319-14
Table 2-4. ORGANIZATIONAL TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
ROLLERS DO NOT ROTATE WHEN CIRCUIT BREAKER AND DRIVE SWITCHES ARE ON.
Step 1.
Check for blown fuse as follows:
WARNING
Death or serious injury may occur from electrical shock unless power is
t u r n e d o f f b e f o r e s e r v i c i n g.
( a ) T u r n c i r c u i t b r e a k e r o f f .
(b) Remove retaining screws and front panel.
(c) Remove fuse FU4 from holder.
(d) Connect multimeter probes to fuse and check for continuity.
2-75