Table 2-4. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
ROLLERS DO NOT ROTATE WHEN CIRCUIT BREAKER AND DRIVE SWITCHES ARE ON - Cont
( 1 ) I f f u s e i s g o o d , p r o c e e d t o s t e p 2 .
(2) If fuse is open, replace fuse.
Step 2.
Check continuity of drive switch.
( a ) I f s w i t c h i s d e f e c t i v e , r e p l a c e d r i v e s w i t c h ( p a r a g r a ph
2 - 1 6 . 8 ).
( b ) I f s w i t c h i s n o t d e f e c t i v e , r e f e r t o d i r e c t / g e n e r a l s u p p o rt
maintenance.
2. CENTRIFUGAL FAN DOES NOT BLOW AIR WHEN MAIN POWER AND DRYER SWITCHES ARE ON.
Step 1.
Check for blown FU1 or FU2 fuse.
WARNING
Death or serious injury may occur from electrical shock unless power is
t u r n e d o f f b e f o r e s e r v i c i n g.
( a ) T u r n o f f c i r c u i t b r e a k e r .
2-76