TM 5-6675-319-14
Table 2-4. ORGANIZATIONAL TROUBLESHOOTING - Cont
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. AFTER WARM-UP, DEVELOPER SOLUTION TEMPERATURE IS ABOVE 80°F (26.6°C) AND
DEVELOPER HEATER IS NOT ACTIVATED.
R e p l a c e c h i l l e r ( p a r a g r a p h 2 - 1 6 . 1 0 ).
7. REPLENISHMENT PUMP DOES NOT ACTIVATE WHEN PAPER IS FED.
Step 1. Check for improperly adjusted film detector crossover as follows:
(a) Remove top cover.
(b) Turn off DRIVE switch.
(c) Turn on PUMP switch.
( d ) L i f t u p o n d e t e c t o r s w i t c h l o c a t e d a b o v e r o l l e r a n d l i s t e n f o r r e p l e n-
ishment pump activation.
(1) If pump does not activate, proceed to step 2.
(2) If pump activates, adjust film detector crossover assembly
(paragraph 2 - 16 . 7).
2-83