TM 5-6675-318-14
Section III OPERATOR MAINTENANCE
5 - 8 .
LUBRICATION INSTRUCTIONS.
This equipment does not require lubrication.
5-9.
TROUBLESHOOTING PROCEDURES.
a.
The table lists the common malfunctions which you may find during operation
or maintenance of the automatic battery charger.
You should perform the test/
inspections and corrective actions in the order listed .
b. This manual cannot list all malfunctions that may occur, nor all test or
inspections and corrective actions.
I f a m a l f u n c t i o n i s n o t l i s t e d o r i s n o t
c o r r e c t e d b y l i s t e d c o r r e c t i v e a c t i o n s , n o t i f y y o u r s u p e r v i s o r .
Table 5-2. TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NO CHARGING CURRENT IS INDICATED ON AMMETER.
Step 1.
Check to see if power cord is plugged in.
(a) If power cord is plugged in, proceed to step 2.
(b) Plug in power cord.
Step 2.
Visually check to see if fuse F1 is blown.
(a) If fuse is good, proceed to step 2.
(b) Replace defective fuse (paragraph 5-10.1).
Step 3.
Check connections at battery.
(a) If connections are clean and tight, proceed to step 4.
(b) Clean battery terminals and reposition clamps.
Step 4.
Check for sulfated battery.
Replace battery.
5-9