TM 5-6675-318-14
Table 5-1. OPERATOR PREVENTIVE MAINTENANCE CKECKS AND SERVICES
NOTE
If the equipment must be kept in continuous operation, check
and service only those items that can safely be checked and
s e r v i c e d w i t h o u t d i s t u r b i n g o p e r a t i o n .
Make the complete
checks and services when the equipment can be shut down.
B - Before
W - Weekly
AN - Annually
(Number) - Hundreds of Hours
D - During
M - Monthly
S - Semiannually
A - After
Q - Quarterly
BI - Biennially
1
B
ITEM TO BE INSPECTED
PROCEDURE
AUTOMATIC BATTERY CHARGER
Inspect.
1 . Unplug power cord.
2 .
Carefully inspect power cord for cracked or broken
p l u g , l o o s e p i n s , f r a y e d o r c u t i n s u l a t i o n , b r o k en
wires, kinks, and breaks.
3 . I n s p e c t b a t t e r y c l i p s f o r c o r r o s i o n a n d w e ak
s p r i n g s.
4 . I n s p e c t b a t t e r y c a b l e s f o r b r o k e n w i r e s , k i n k s,
and frayed or cut insulation .
5.
Inspect meter face for scratches and cracked glass.
Report defective meter to direct/general support.
6 . C h e c k t h a t v e n t i l a t i n g g r i l l e s a r e f r e e o f d e b r i s .
C l e a n g r i l l e s .
7.
Inspect rear and sides for loose or missing screws.
Replace missing screws.
For Readiness
Reporting,
Equipment is
Not Ready/
Available If:
Power cord
i s d e f e c t i v e.
Battery clip
i s d e f e c t i v e.
B a t t e ry
cables are
d e f e c t i v e .
5-6
I T E M
NO.
IN
TER-
VAL
