TM 5-6675-315-14
2-16.20 Replace Pressure Safety Switch.
MOS:
83FJ6, Reproduction Equipment Repairer
TOOLS:
6 mm Hex Head Key Wrench
WARNING
Death or serious injury may occur from electrical shock unless power is turned off before
servicing.
a.
Turn off circuit breaker.
b.
Turn off main power switch.
c.
Remove rear switch cover panel.
d.
Tag and disconnect switch wiring.
e.
Rotate slide locking tab cover and pull off bottom half of switch.
f.
Unscrew mounting ring from top half of switch and lift out.
g.
Insert top half of new switch and screw on mounting ring.
h.
Attach bottom half of switch and rotate locking tab in place.
i.
Reconnect switch wiring.
j.
Reinstall cover panel.
k.
Turn on circuit breaker.
l.
Turn on main power switch.
2-126