TM 5-3610-287-24
2-68.
REPAIR HANDWINCH (CONT)
WARNING
Cable must not be under load during the following procedure.
Attempting replacement of worm gear while cable is supporting
folding floor may result in floor falling and cause serious
personal injury.
1. Remove nut (1) and handle (2)
2. Remove hex bolts (3) and worm gear assembly (4).
3.
Install new worm gear assembly (4) with hex bolts (3).
4.
Install handle (2) with nut (1).
WARNING
Stay clear as folding floors are raised or lowered. Weight
of floors may cause serious injury.
5.
Test operate by raising and lowering folding floor.
2-213