TM 5-3610-287-24
2-60. REPAIR WALL HEATER (CONT)
WARNING
ELECTRICAL HAZARD. There are two heater circuit breakers.
repaired to off. Failure to observe this warning may
result in death or serious injury.
Do not operate wall heater with grill removed or with wall
heater assembly removed from enclosure. Failure to
observe this warning may result in serious personal
injury.
1.
Set specific HEATER circuit breaker to OFF.
2.
Remove control knob (1) by pulling gently.
2-188