TM 5-3610-287-24
REPAIR POWER MONITOR ASSEMBLY (CONT)
2-50.
Rest power
2.
monitor assembly (2) on load center.
3.
Tag wires (3) and remove hex nuts (4), flatwashers, and wires (3).
4.
Remove hex nuts (5), flatwashers, and voltage meter (6).
5.
Install new voltage meter (6) with hex nuts (5) and flatwashers.
6.
Install wires (3) with hex nuts (4) and flatwashers.
7.
Install power monitor assembly (2) with hex bolts (1), lockwashers,
and flatwashers.
WARNING
ELECTRICAL HAZARD. Do not connect power cable to Section
before grounding. Failure to observe this warning may
result in death or serious injury.
8.
Ground Section and connect main power cable.
9.
Test operate by checking for correct phase and voltage (TM 5-3610-
10.
Set MAIN POWER switch to ON.
INITIAL SETUP
Tools
Light machine repair tool kit (appendix B, section III, item 11)
Flat-tip screwdriver
Socket wrench set
Combination wrench set
Extension light
Materials/Parts
2-151