TM 5-3610-287-24
2-48. REPAIR POWER ENTRY PANEL ASSEMBLY (CONT)
WARNING
ELECTRICAL HAZARD. Turn off main power switch and
disconnect Section from power source before replacing duplex
receptacle. Failure to do so may result in death or serious
injury.
1.
Set MAIN POWER switch to OFF and disconnect main power cable.
2.
Remove screws (1), lockwashers, flatwashers, and power entry panel
cover (2).
NOTE
An extra person outside Section is required for the
following procedure.
3.
Inside Section at duplex receptacle (3), remove hex nuts (4) and
lockwashers.
4.
Outside Section, remove waterproof cover (5) and screws (6).
5.
Outside Section, remove screws (8) from duplex receptacle (3). Pull
6.
duplex receptacle (3) out.
7.
Outside Section at duplex receptacle (3), tag and disconnect
wires (9).
8.
Scrape silicone compound from power entry panel and waterproof
cover (5).
9.
Connect wires (9) to new duplex receptacle (3).
10.
Install duplex receptacle (3) with screws (8).
11.
WARNING
CHEMICAL HAZARD. Use silicone compound in a well-ventilated
area. Silicone compound is harmful to eyes and skin. In
case of contact with eyes, immediately flush eyes with water
for 15 minutes, then seek medical help. In case of contact
with skin, wipe off with dry cloth, then wash with soap and
water.
12.
Outside Section, apply silicone compound to back of waterproof cover
(5) and install with screws (6).
2-144