TM 5-3610-287-24
2-21.
REPAIR EMERGENCY LIGHT SET (CONT)
WARNING
ELECTRICAL HAZARD. Unplug emergency light power cord before
replacing circuit board. Failure to do so may result in
death or serious injury.
Turn off emergency light and unplug power cord.
1.
2.
Remove screws (1) securing emergency light cover (2) to emergency light
set (3).
3.
Disconnect both wires from battery (4) and remove battery (4).
4.
Remove bulb (5) from circuit board (6).
2-58