TM 5-3610-287-24
2-21.
REPAIR EMEERGENCY LIGHT SET (CONT)
WARNING
ELECTRICAL HAZARD. Unplug emergency light power cord before
replacing toggle switch. Failure to do so may result in
death or serious injury.
1.
Turn off emergency light and unplug power cord.
2.
Remove screws (1) securing emergency light cover (2) to emergency
light.
Disconnect positive (red) lead from battery (3).
3.
Remove hex nut (4), flatwasher (5), ON/OFF plate (6), and key (7)
4.
securing toggle switch (8) to emergency light cover.
Remove toggle
5.
Tag and desolder two wires from switch terminals.
switch (8).
Solder two wires to terminals of new toggle switch (8).
6.
7.
Install toggle switch on emergency light cover with key (7), ON/OFF
plate (6), flatwasher (5), and hex nut (4).
8.
Connect positive (red) lead to battery (3).
9.
Install emergency light cover (2) on emergency light with screws (1).
10 l
Plug in emergency light power cord and turn on emergency light.
Push TEST button (9) down to test operate.
11.
LIGHT BULB
INITIAL SETUP
Tools
Light machine repair tool kit (appendix B, section III, item 11)
Flat-tip. screwdriver
Materials/Parts
Light bulb, 1130
2-54