TM 5-3610-287-24
2-13.
REPAIR EXTERNAL EXHAUST FAN HOUSING ASSEMBLY (CONT)
1.
Scrape gasket sections (1) from exhaust fan door (2).
WARNING
CHEMICAL HAZARD. Use rubber cement thinner in a well-
ventilated area. Failure to do so may result in damage to
respiratory system. Wear gloves and goggles to prevent
injuries to skin and eyes.
2.
Remove adhesive from exhaust fan door (2) with rubber cement thinner.
WARNING
CHEMICAL HAZARD. Use adhesive in a well-ventilated area.
Adhesive is harmful to eyes and skin. In case of contact
with eyes, immediately flush eyes with water for 15 minutes,
then seek medical help. In case of contact with skin, wipe
off with dry cloth, then wash with soap and water.
3.
Apply adhesive around edges of exhaust fan door (2) and install gasket
sections (l).
REPLACE REMOVABLE FLOOR
SECTION CARRIER BRACKETS
This task covers: a. Removal b.
Installation
INITIAL SETUP
Tools
Light machine repair tool kit (appendix B, section III, item 11)
Portable electric drill
Twist drill set
Materials/Parts
Carrier bracket, 13226E7976-1
Carrier bracket, 13226E7976-2
Rivet, MS20600-MP4W6
Rivet, MS20600-AD6W4
Equipment Conditions
Curbside expanding side expanded with folding floor in down position
2-39