TM 5-3610-287-24
2-13.
REPAIR EXTERNAL EXHAUST FAN MOUSING ASSEMBLY (CONT)
1.
2.
Drill out rivets (1) securing hinge (2) and spacer (3) to housing
assembly (4).
3.
Drill out rivet (5) securing brace (6) to exhaust fan door (7).
WARNING
CHEMICAL HAZARD. Use adhesive in a well-ventilated area.
Adhesive is harmful to eyes and skin. In case of contact
with eyes, immediately flush eyes with water for 15 minutes,
then seek medical help. In case of contact with skin, wipe
off with dry cloth, then wash with soap and water.
4.
Apply adhesive around edges of new exhaust fan door (7) and install
four gaskets (8).
2-37